In mobile applications, hydrogen is stored in the tank at a pressure of up to 1050 bars. Our high-pressure valve regulates the pressure range and the hydrogen medium, taking up less space when applied as an OTV (on tank valve).
Details
- Nominal Working Pressure (NWP): 0 … 700 bars
- Maximum pressure (MAWP): 1050 bars
- Nominal width: 2.7 mm
- Type of Voltage: DC, PWM
- Protection Class: IP6K9K
- Tested according to EC79
- Options:
- Various electrical plug connections
- ATEX version for stationary applications
- Customer-specific mechanical interface
- Versions for natural gas (CNG)
This device is a base unit for customer-specific developments and implementations.
- Dimension (Ø): 32 mm
- Function: 2/2 NC
- Medium: hydrogen H2
Other series within this product group